TM 55-8145-221-14&P
RERIGERATED CONTAINER SYSTEM
PREVENTIVE MAINTENACE CHECKS AND SERVICES (PMCS) Continued
0012 00
Table 3. Preventive Maintenance Checks and Services for Refrigeration Container System
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
REFRIGER-
ATION UNIT
_________
WARNING
High voltage and exposed rotating
parts are contained in the refrigeration
unit. Personal injury can result if
power is connected with doors open.
NOTE
If the refrigeration unit is not going to
be used for several days, it must be
pumped. Notify Unit Maintenance.
1.
After
0.5
Perform after PMCS on refrigeration unit per
TM 9-4110-258-13.
Not operational.
2.
After
0.5
GENERATOR
SET
Perform after PMCS on generator set per TM
9-6115-642-10.
Not operational.
NOTE
If the equipment must be kept in
service for continuous operation, check
only those items that can be checked
and
serviced
without
disrupting
operations. Complete all checks and
services when equipment is shut down.
3.
After
0.1
Auxiliary Fuel
Tank
Check fuel level and fill as required.
0012 00-5
Change 1
|