TM 55-8145-221-14&P
RERIGERATED CONTAINER SYSTEM
PREVENTIVE MAINTENACE CHECKS AND SERVICES (PMCS) Continued
0012 00
Table 4. Preventive Maintenance Checks and Services for Refrigeration Container System
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED
OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
EXTERIOR
1.
Weekly
0.1
Door Hardware
(Rear Doors)
a.
Inspect for broken or missing
handle locks.
Broken or badly
bent handles.
b.
Inspect for broken lock keepers.
Broken keepers.
2.
Weekly
0.1
Door (Rear)
c.
Inspect door hinges for cracked or
broken hinges.
Door hinge cracked
top to bottom.
3.
Weekly
1.0
REFRIGER-
ATION UNIT
Perform weekly PMCS on refrigeration unit
per TM 9-4110-258-13.
Refrigeration unit
not operational.
4.
Weekly
1.0
GENERATOR
SET
Perform weekly PMCS on Generator Set
per TM 9-6115-642-10.
Generator set not
operational.
5.
Weekly
0.1
Recorder
Thermometer
Inspect the recorder thermometer for
cracked or missing lens and loose or
missing mounting hardware. If damaged or
loose, notify Unit Maintenance to tighten
or replace it as necessary.
Not operational.
Change 1
0012 00-6
|