TM 55-8145-221-14&P
RERIGERATED CONTAINER SYSTEM
PREVENTIVE MAINTENACE CHECKS AND SERVICES (PMCS) Continued
0012 00
Table 5. Preventive Maintenance Checks and Services for Refrigeration Container System
ITE
M
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED
OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
EXTERIOR
1.
Monthly
0.1
Door (rear)
a. Inspect Container frame around
doors for cracks, splits and broken
welds.
Container frame
cracked.
.
b. Inspect seals for cracks and
damage.
Torn and damaged.
2.
Monthly
0.1
Left Side Panel
Inspect container upper and lower
sides for cracks, splits, and broken
welds.
Container frame
cracked.
3.
Monthly
0.1
Ladder
Inspect for cracked welds and bent
frame.
4.
Monthly
0.1
Roof Panel
Inspect for obvious damage, cracks,
splits and delamination.
Cracked or
punctured through
interior.
5.
Monthly
1.0
Refrigeration
Unit
Perform Monthly PMCS on
refrigeration unit per
TM 9-4110-258-13.
Refrigeration unit
not operational.
6.
Monthly
0.1
Right Side Panel Inspect container upper and lower
sides for cracks, splits, and broken
welds.
Container frame
cracked.
7.
Monthly
0.1
Generator Set
Perform Monthly PMCS on Generator
Set per TM 9-6115-642-10.
Generator set not
operational.
8.
Monthly
0.1
Container
Inspect for corrosion and condition of
paint.
9.
Monthly
0.1
Name Plates
Inspect for missing, damaged or
illegible name plates.
0012 00-7
Change 1
|