TM 55-8145-221-14&P
REFRIGERATED CONTAINER SYSTEM
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES Continued
0018 00
Table 1. Unit Preventive Maintenance Checks and Services for Model RCS800 Continued.
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
INTERIOR
5.
Weekly
0.1
Temperature
Recorder
Sensing Bulb
a. Inspect sensing bulb for dents, kinks in
sensing line, and obvious damage.
Sensing bulb
damaged.
0.1
b. Check security of mounting hardware.
Missing mounting
screws.
EXTERIOR
6.
Monthly
0.1
Container Frame
Inspect for cracked, bent or broken corner
fittings and frame members.
Frame or welds
cracked.
INTERIOR
7.
Monthly
1.0
Refrigeration
Unit
Perform Monthly PMCS on Refrigeration
Unit (TM 9-4110-258-13).
Not Operational.
8.
Monthly
1.0
Generator Set
Perform Monthly PMCS on Generator Set
(TM 9-6115-642-10).
9.
Monthly
0.1
Container frame
Inspect for bare metal and corrosion.
EXTERIOR
10.
Annually
1.0
Refrigeration
Unit
Perform Annual PMCS on Refrigeration
Unit (TM 9-4110-258-13).
11.
Annually
1.0
Generator Set
Perform Annual PMCS on Generator Set
(TM 9-6115-642-10).
END OF WORK PACKAGE.
0018 00-3/4 blank
Change 1
|