TM 55-8145-221-14&P
0022 00-1
REFRIGERATED CONTAINER SYSTEM
GENERATOR SET SLIDES
0022 00
THIS WORK PACKAGE COVERS:
Removal / Installation
INITIAL SET-UP:
Maintenance Level:
Unit
Tools:
Equipment Condition:
General Mechanics Tool Kit (Section III, Item 1, WP 0048 00)
Generator Set removed (WP 0021 00)
Personnel Required:
Two
Material/Parts:
Lock Washers (Item 28, WP 0081 00)
Lock Washers (Item 29, WP 0081 00)
Rivets (Item 12, WP 0081 00)
REMOVAL.
1. Remove twelve screws (1), lock washers (2), flat washers (3), eight screws (4) and generator mount plate (5). Discard
lock washers (2).
2. Remove six screws (6), lock washers (7), and flat washers (8), from each of the two slides (9). Discard lock washers (7).
3. Remove six screws (10) and three slide mounts (11) from each slide (9).
4. Drill out two rivets (12) and remove two generator locking bolt lanyards (13).
INSTALLATION.
1. Install three slide mounts (11) on bottom of each slide (9) and secure with six screws (10).
2. Install two slides (9) on frame (14) and secure with six flat washers (8), new lock washers (Item 29, WP 0081 00) (7),
and screws (6). Hand Tight Only.
3. Position generator mount on both slides (9) and secure with twelve flat washers (3), new lock washers (Item 28, WP
0081 00) (2), and screws (1).
4. Tighten six screws (6) installed in step 2.
5. Secure two generator locking bolt lanyards (13) to generator mounting plate (5) with two rivets (Item 12, WP 0081 00)
(12).
|