TM 55-8145-221-14&P
0023 00-3/4 blank
REFRIGERATION UNIT Continued
0023 00
INSTALLATION.
1.
Open right rear door (1).
CAUTION
Position personnel inside and outside container to guide Refrigeration Unit into
position on front panel. Damage to front panel of Refrigeration Unit can result if
unit strikes front panel.
Forklift tines must not protrude beyond tine guides on Refrigeration Unit. Front
panel will be damaged if tines contact panel.
2.
If cover plate (2) is installed on front panel (3), remove four nuts (4), lock washers (5), and flat washers (6). Stow plate
inside container (7). Discard lock washers (5).
3.
Apply a bead of sealant (Item 3, WP 0078 00) on outside surface opening of frame (8) just prior to installing
Refrigeration Unit (9).
4.
Using forklift, carefully guide Refrigeration Unit (9) into position on front panel (3) and studs (10).
5.
Open both side doors (11).
6.
Install four flat washers (6), lock washers (5) (Item 32, WP 0078 00) and nuts (4).
7.
Remove forklift from Refrigeration Unit (9).
8.
Close both side doors (11).
9.
Open cable storage compartment door (12), remove cable (13) (approx. six feet) and close door.
10. Connect refrigeration power cable (13) to generator power cable (14).
11. Close right rear door (1).
END OF WORK PACKAGE.
|