TM 55-8145-221-14&P
0024 00-1
MANUAL HOLDER REPAIR
0024 00
THIS WORK PACKAGE COVERS:
Removal, Disassembly, Inspection, Repair, Assembly, and Installation
INITIAL SET-UP:
Maintenance Level
Material/Parts:
Unit
Drive rivets (Item 18, WP 0081 00)
Tools:
Rivets, Blind (Item 16, WP 0081 00)
General Mechanics Tool Kit (Section III, Item 1, WP 0048 00)
Gasket (Item 3, WP 0079 00)
Portable Drill (Section III, Item 2, WP 0048 00)
Adhesive (Item 1, WP 0078 00)
Drill Bit Set (Section III, Item 2, WP 0048 00)
Sealant (Item 3, WP 0078 00)
Rivet Tool (Section III, Item 10, WP 0048 00)
Equipment Condition:
Refrigeration Unit shut down (WP 0006 00)
Generator Set shut down (WP 0006 00)
REMOVAL.
NOTE
Manual holders are similar and are repaired the same way. Manual holder on front panel
is shown being repaired. There is no lanyard on the manual holder mounted on the right
rear door.
1.
Unfasten two latches (1) and remove cover (2) from box (3).
2.
Drill out ten rivets (4) and remove box (3) from front panel (5).
3.
Remove sealant from mounting surfaces of box (3) and front panel (5).
DISASSEMBLY.
NOTE
Disassemble components only to the level required to perform repair.
1.
Drill out two rivets (6) and remove lanyard (7).
2.
Drill out four rivets (8) and remove two latches (1) from box (3).
3.
Drill out four rivets (8) and remove two latch hooks (9) from cover (2).
4.
Remove gasket (10) from cover (2).
INSPECTION.
1.
Inspect box (3) and cover (2) for cracks.
2.
Inspect latches (1) for cracks or broken springs.
REPAIR.
1.
Replace defective components.
ASSEMBLY.
1.
Apply adhesive (Item 1, WP 0078 00) to inside surface of cover (2).
2.
When adhesive (Item 1, WP 0078 00) becomes tacky, press gasket (10) (Item 3, WP 0079 00) in place on cover (2).
|