TM 55-8145-221-14&P
0039 00-1
FLOOR DRAIN REPLACEMENT
0039 00
THIS WORK PACKAGE COVERS:
Removal and Installation
INITIAL SET-UP:
Maintenance
Unit
Tools:
Equipment Condition:
General Mechanics Tool Kit (Section III, Item 1, WP 0048 00)
Refrigeration Unit shut down (WP 0006 00)
Material/Parts:
Generator Set shut down (WP 0006 00)
Sealant (Item 3, WP 0078 00)
NOTE
There are four drains in the container floor. Removal of one drain is shown; the others
are similar.
REMOVAL.
1.
Open right rear door (1) and then left rear door (2).
2.
Remove drain plug (3) from floor drain (4).
3.
Remove sealant from around floor drain (4) both inside the container and under the container.
4.
Push floor drain (4) through the bottom of floor assembly (5).
5.
Clean any residue sealant from floor assembly (5).
INSTALLATION.
NOTE
There are four drains in the container floor. Installation of one drain is shown; the others
are similar.
1.
Install floor drain (4) into floor assembly (5) until drain is .25 inch below the surface.
2.
Apply a bead of sealant (Item 3, WP 0078 00) around top and bottom edge of floor drain (4).
3.
Allow sealant to dry.
4.
Install drain plug (3).
5.