TM 55-8145-221-14&P Change 1 0005 00-10 2 (2) REFRIGERATED CONTAINER SYSTEM CONTROLS AND INDICATORS – Continued   0005 00 GENERATOR SET - FREQUENCY ADJUST CONTROL (Figure 6). The frequency adjust control is to the left and below the control panel. Figure 6.  Frequency Adjust Control LOCKING RING (1). Turn locking ring counterclockwise to unlock frequency adjust control.  Turn locking ring clockwise to lock frequency adjust control at desired setting. FREQUENCY ADJUST BUTTON (2). Press frequency adjust button and pull frequency adjust knob to increase frequency.  Press frequency adjust button and push frequency adjust knob to decrease frequency.  This enables a rapid adjustment of frequency. FREQUENCY ADJUST KNOB (3). Turn knob clockwise to increase frequency and counterclockwise to decrease frequency.  This provides a fine adjustment in frequency. 1 3 COUNTER- CLOCKWISE CLOCKWISE (3) (1)