REFRIGERATED CONTAINER SYSTEM
CONTROLS AND INDICATORS Continued
0005 00
GENERATOR SET DEAD CRANK SWITCH (Figure 7).
The dead crank switch (1) is located in the engine compartment on the right side as viewed from the exhaust end of generator
set. For maintenance purposes the switch allows the engine to be cranked without starting. During normal operations, the
dead crank switch must be in the normal position for the generator set to start properly. If the dead crank switch is in the off
position, the generator set will not start.
(CRANK position).
This position of the switch allows the engine to be cranked without starting.
(OFF position).
This position of the switch allows the engine to be shut down for maintenance purposes.
(NORMAL position).
This position of the switch allows the engine to be started properly for normal operations.
Figure 7. Generator Set Dead Crank Switch
VIEW ROTATED
90 CW
FOR CLARITY
1
FRONT VIEW
NORMAL
OFF
CRANK
|