TM 9-4110-241-13
TO 35E9-274-1
4-29. (MODELS MDS1600N, TKR400C AND TKR4000OC). REMOVE/TEST/INSTALL MALE RECEPTACLE, CAP
AND CHAIN.
a. Tools: Screwdriver, cross-tip; Multimeter.
b. Removal:
WARNING
Disconnect male power receptacle before beginning this procedure.
(1) Loosen and remove screws with screwdriver.
(2) Gently pull male receptacle and cap and chain away from door frame to gain access to using panel assembly.
(3) Tag and disconnect wires at rear of receptacle.
Figure 4-23. Male Receptacle (Models MDS1600N, TKR-600C, and TKR-4000C)
c. Test:
(1) With multimeter, perform isolation testing across the two plug terminals, and across each plug terminal and
the ground terminal or receptacle case. Multimeter shall indicate infinite resistance across both plug terminals
and across each plug terminal and the ground terminal. Otherwise, receptacle is defective and shall be
replaced.
d. Installation
(1) Connect wires to receptacle terminals as tagged and remove wire tags.
(2) Position receptacle and cap and chain onto door frame panel assembly.
Secure with screws using
screwdriver.
(3) Reconnect power to power receptacle.
4-46 CHANGE 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |