![]() TM 9-4110-241-13
TO 35E9-274-1
4-28. (MODELS AA600PF, AA1200PFA, AND AA4000PF). REMOVE/TEST/INSTALL POWER RECEPTACLE.
b. Removal:
WARNING
Disconnect power to power receptacle before beginning this procedure.
(1) Remove screws and gently pull power receptacle away from wall.
(2) Tag and disconnect wires to rear of receptacle.
Figure 4-22. Power Receptacle (Models AA600PF, AA1200PFA, and AA4000PF)
c. Test:
(1) Attach a 125VAC power source to terminals of receptacle.
(2) Use a multimeter to check for current flow through receptacle.
d. Installation:
(1) Connect wires to rear of receptacle and remove wire tags.
(2) Position receptacle into wall and secure with screws.
(3) Reconnect power to power receptacle.
4-45
|