4-27. (MODELS MDS1600N, TKR400C, TKR4000C). REMOVE/TEST/INSTALL FEMALE ELECTRICAL.
a. Tools: Screwdriver, flat-tip; Pocket Knife; Multimeter.
WARNING
Shut off power supply at its source before beginning this procedure.
b. Removal:
(1)
Slide boot off female receptacle.
(2)
Loosen retaining damp screws with screwdriver.
(3)
Separate halves of female receptacle.
(4)
Tag and disconnect wires to female receptacle.
Figure 4-21. Female Receptacle (Models MDS1600N, TKR-600C, and TKR-4000C Only)
c. Test:
(1) With multimeter, check for isolation across both receptacle wire terminals and across each wire terminal and
the ground terminal. Multimeter shall indicate infinite resistance. Otherwise receptacle is damaged and shall
be replaced.
(2) With multimeter check for continuity across each wire terminal at rear of connector and its corresponding plug
terminal at the font end. Multimeter shall indicate continuity.
d. Installation:
(1)
Slide cap of female receptacle onto the power cord.
(2)
Connect wires to terminals of female receptacle.
(3)
Snap halves of female receptacle together.
(4)
Using screwdriver, tighten screws to secure power supply cord to clamp.
(5)
Side boot over female receptacle.
CHANGE 1 4-43/(4-44 blank)
|