TM 9-4110-241-13
TO 35E9-274-1
CHAPTER 5
DIRECT SUPPORT MAINTENANCE INSTRUCTIONS
Page
Troubleshooting
Direct Support Maintenance Procedures
Section I. TROUBLESHOOTING
5-1. GENERAL.
There is no direct support troubleshooting. All troubleshooting actions can be performed at the operator or unit level of
maintenance.
Section II. DIRECT SUPPORT MAINTENANCE PROCEDURES
5-2. REPAIR REFRIGERATOR PANELS.
a. Tools and Materials: Polyurethane Foam Kit, MIL-P-39500 (App. E, Item 5); Rivets (App. E, item 8).
b. Procedure:
(1) Sheet mal patches may be fabricated from 0.040 inch sheet metal to cover hole extending more than 6 inches
in any direction. Fasten with pop rivets (App. E, Item 8).
(2) Fill cavity in panel (behind patch area) using polyurethane foam in accordance with instructions in kit (App. E,
Item 5).
(3) Rivet patch into place. Determine rivet size at assembly (Appendix E, Item 8).
5-1/(5-2 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |