| |
TM 9-4110-257-14
c.
Installation.
(1) If removed, install dummy stowage connector (28), four bolts (31), cover (29), and four new self locking nuts
(30).
(2) If removed, install temperature control bracket (24), two screws (27), flat washers (26), and new self locking
nuts (25).
(3) Install remote bulb thermostat (13), sensing bulb (12), and grommets (22) and (23).
(4) Install remote bulb thermostat (13), four flat washers (21), bolts (20), and new self locking nuts (19).
(5) Install tie down straps (18) as necessary.
(6) Install grommet (17) and push wire leads (15) into remote bulb thermostat (13).
(7) Using tags and wiring diagram (fig. 1-4), install wire leads (15) and two screws (16). Remove tags.
(8) Slip clamp (11) over sensing bulb (12).
(9) Install clamps (11) and (14), sensing bulb bracket (8), bolt (10), and new self locking nut (9).
(10)
Install sensing bulb bracket (8), two bolts (7), and new self locking nuts (6).
(11)
Install cover (5) and screw (4).
(12)
Close control panel (3) and install two new lock washers (2) and bolts (1).
(13)
Apply silicone RTV into evaporator frame grommets (22) to seal evaporator enclosure.
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control panel cover door.
Close left side condenser door.
Install evaporator air outlet guard (para 4-17).
Install evaporator coil guard (para 4-18).
Connect battery (para 4-35) and put unit back into service.
4-75
|