TM 9-4110-257-14
(3)
Using multimeter set to measure continuity, check continuous duty solenoid (7) continuity between
small terminal lugs. Continuity should be indicated. If continuity was not indicated, replace continuous duty
solenoid.
(4)
Using multimeter set to measure continuity, check continuous duty solenoid (7) continuity between
large terminal lugs. Continuity should not be indicated. If continuity was indicated, replace continuous duty
solenoid.
(5)
Check continuity between each terminal and the case. No continuity should be indicated. If
continuity was indicated, replace continuous duty solenoid.
NOTE
Terminal hardware is supplied with continuous duty solenoid.
(6)
If no failure was indicated, install wire leads (4) per tags and wiring diagram (fig. 1-4), lock
washers (6), and nuts (5). Remove tags.
(7)
Close control panel (3) and install two new lock washers (2) and bolts (1).
b.
Removal.
(1)
Be sure battery has been disconnected and remove two bolts (1) and lock washers (2). Open
control panel
(3).
Discard lock washers.
NOTE
Terminal hardware is supplied with continuous duty solenoid.
(2)
Tag wire leads (4) and remove nuts (5), lock washers (6) and wire leads.
(3)
Remove two bolts (8), lock washers (9), flat washers (10) and continuous duty solenoid (7).
Discard lock washers.
c. Installation.
(1)
Install continuous duty solenoid (7), two bolts (8), new lock washers (9) and flat washers (10).
NOTE
Terminal hardware is supplied with continuous duty solenoid.
(2)
Using tags and wiring diagram (fig. 1-4), install wire leads (4), lock washers (6) and nuts (5).
Remove tags.
(3)
Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control panel cover door.
Connect battery (para 4-35) and put unit back into service.
4-87
|