TMIA 9-4110-257-14 4-43. IDLER PULLEY REPLACEMENT. This task covers: a. Testing b. Removal c. Installation INITIAL SETUP: Materials/Parts: General Safety Instructions: Lock Washers (4) WARNING 13, Appendix G Equipment Conditions: Exposed  rotating parts are used  in the Refrigeration unit shut down (para 2-7) and battery refrigeration unit.  Personal injury can result if disconnected (para 4-35). battery is connected. a. Removal. (1) Loosen bolt (1) to relax tension on fan belt. Figure  4-37.   Idler Pulley (2) Slide idler arm (2) off idler bracket (3). (3) Remove set screw (4), and slide bushing (5) and pulley (6) off idler shaft (7). (4) Remove idler shaft (7) from idler arm (2).  Remove lubrication fitting (8). (5) Remove four bolts (9), lock washers (10) and idler bracket (3).  Discard lock washers. 4-108