TM 9-4110-257-14
4-63. FUEL GAGE REPLACEMENT.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP:
Materials/Parts:
Equipment Conditions:
Marker tags (3)
Refrigeration unit shut down (para 2-7) and battery
7, Appendix E
disconnected (para 4-35).
Left side condenser door open.
a.
Removal.
(1) Tag wire leads (1).
Figure 4-57. Fuel Gage
NOTE
Terminal hardware is supplied with fuel gage.
(2) Remove three nuts (2), and wire leads (1).
(3) Remove three nuts (3) and retainer (4).
(4) Remove fuel gage (5) and three nuts (6).
4-154
|