TM 9-4110-257-14
b.
Installation.
(1) Install fuel gage (5) and three nuts (6).
CAUTION
Overtightening retainer nuts will cause the retainer to deform and
possibly crack or break.
(2) Install retainer (4) and three nuts (3) being careful not to over tighten.
(3) Tighten nuts (6) against retainer (4).
(4) Using tags and wiring diagram (fig. 1-4), install wire leads (1) and secure using three nuts (2). Remove tags.
NOTE
FOLLOW-ON MAINTENANCE:
Close left side condenser door.
Connect battery (para 4-35) and put unit back into service.
4-155
|