Table 4-1. Unit Preventive Maintenance Checks and Services for Model F10000RD - Continued
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/
Procedure
Capable if:
Service
1 -
Cont
Injury to personnel can result if compressed
air used for cleaning purposes exceeds 30
psig (207 kPa). When using compressed air,
wear safety glasses or goggles. Dirt can be
blown into your eyes.
d.
Using compressed air at 30 psig (207 kPa) or
less, blow dirt out of air cleaner.
e.
Install air cleaner and tighten clamp.
2
8 Hours
Engine Oil
Service the engine oil by checking and refilling if
Engine oil level is below
necessary with appropriate oil (fig. 4-6).
minimum mark on dipstick
rod.
a.
Remove dipstick rod and wipe oil from
end. Install and remove again. Check that
oil level indicated is between minimum
and maximum marks. Add oil if
necessary.
4-14