TM 9-4110-257-14
SECTION V. UNIT MAINTENANCE INSTRUCTIONS
4-13.
CONDENSER TOP PANEL REPLACEMENT.
This task covers: a. Removal b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Lock Washers (7)
WARNING
1, Appendix G
Equipment Conditions:
Exposed rotating parts are used in the
refrigeration unit. Personal injury can result if
Refrigeration unit shut down (para 2-7) and battery
battery is connected.
Disconnected (para 4-35).
a.
Removal. Remove seven bolts (1), lock washers (2), and panel (3). Discard lock washers.
b.
Installation. Install panel (3), seven new lock washers (2), and bolts (1).
Figure 4-7. Top Panel
NOTE
FOLLOW-ON MAINTENANCE:
Connect battery (para 4-35) and put unit back into service.
4-38
|