TM 9-4120-367-14
TM 07592B-14/1
Figure 5-4. Rectifier CR1
Location/Item
Installation
Action
a.
b.
c.
d.
e.
f.
Bolt rectifier CR1 to frame using two screws.
Connect quick disconnect terminals.
Terminal Connection
(Models F18H, F18H-3 & F18H-4)
X37A20
V6D20
X38A20
X36A20N
Terminal Connection
(Model MHP-20-4-08)
T1-7<>CR1-1
CR1-2<>TB2-12
T1-8<>CR1-3
K5-9<>CR1-4
1
2
3
4
1 (AC)
2 (+)
3 (AC)
4 (-)
Replace capacitors C1 and C2 or C6.
Install junction box.
Replace top cover.
Connect power supply.
Remarks
Terminal 1 at top.
5-13
5.6 RECTIFIER CR1. - Continued
Wire No.
Terminal No.
Wire No.
Terminal No.
|