TM 9-4120-367-14
TM 07592B-14/1
5.8 RELAYS K4 (AND K5 ON MODEL MHP-20-4-08). - Continued
Location/Item
Action
Remarks
Installation
K4 - 3-Phase Model MHP-20-4-08
- Continued
K4-1<>K2-A1,
1
K4-1<>K5-1
TB1-6<>K4-2
2
J5-A<>K4-3
3
Blank
4
K4-5<>K5-5,
5
K4-5<>K2-B1
Blank
6
Blank
7
J5-C<>K4-8
8
K4-9<>K5-9,
9
K2-X2<>K4-9
K4-10<>K5-10,
10
K4-10<>K2-C1
J5-B<>K4-11
11
K5 - 3-Phase Model MHP-20-4-08
K4-1<>K5-1
1
K5-2-<>TB1-4
2
J3-A<>K5-3
3
Blank
4
K4-5<>K5-5
5
Blank
6
Blank
7
J3-C<>K5-8
8
K5-9<>CR1-4,
9
K4-9<>K5-9
K4-10<>K-5-10
10
J3-B<>K5-11
11
d. Use hot air dryer to heat-shrink tubing on or over
the solder connections.
e. Push relay down into bracket and install the three
nuts and washers.
f. Attach relay and bracket to junction box frame.
g. Replace junction box.
h. Connect power supply.
NOTE: Removal and testing procedure apply to both relays K4 and K5.
5-20
Wire No.
Terminal No.
Wire No.
Terminal No.
|