TM  9-4120-367-14 TM 07592B-14/1 6.5  NITROGEN PURGE. - Continued Location/Item Action Remarks Purge - Continued Nitrogen pressure in the system should not exceed 10 pounds. e.  Open cylinder valve and allow dry nitrogen to flow through system until all moisture is forced out (not less than 5 minutes). f.    Close  cylinder  valve. g.  Close both charging valves. h.  Disconnect all hoses. Figure 6-3. Nitrogen Tank Connection 6-17