TM 9-4120-367-14
TM 07592B-14/1
6.7 REFRIGERANT CHARGEING WITH GAS. This task covers procedures to add refrigerant gas to a system which
is low on refrigerant.
INITIAL SETUP
Applicable Configurations:
All
Test Equipment:
Multimeter
Special Tools:
None
Materials/Parts:
Charging Manifold
Safety Glasses
Cleaning Cloths
Refrigerant R-22
Tools (Paragraph 3.1)
Thermal Gloves
Equipment Descriptions:
Power OFF; installed in or removed from shelter
Special Environmental Conditions:
None
General Safety Instructions:
See WARNING page
References:
None
Troubleshooting References:
None
Personnel Required:
Direct Support
Location/Item
Charging
Action
Use great care to avoid contact with liq-
uid refrigerant or refrigerant gas being
discharged from any container under
pressure. Sudden and irreversible tissue
damage can result from freezing. Wear
thermal protective gloves and a face pro-
tector or safety glasses in any situation
where skin-or-eye-contact is possible.
Prevent contact of refrigerant gas with
flame or hot metal surfaces. Heat
causes the refrigerant to breakdown and
form carbonyl chloride (phosgene), a
highly toxic and corrosive gas.
Remarks
6-20
|