TM 9-4120-367-14
TM 07592B-14/1
6.24 CONDENSER FAN AND MOTOR. - Continued
Location/Item
Removal
Continued
Installation
Action
d.
e.
g.
h.
k.
a.
b.
Do not hammer fan on or off motor shaft;
motor bearings would be damaged.
Dress out roughness with a fine file,
stone, or abrasive cloth. Apply a coating
of light machine oil to ease assembly.
NOTE
If fan only is to be replaced, it is not
necessary to remove motor.
Loosen setscrew in fan (impeller) hub.
Pull fan (impeller) from motor shaft or adapter.
Loosen setscrew.
Pull collar or adapter from motor shaft.
Remove four screws and washers which secure
motor and fan assembly to the frame.
Remove four screws, flat washers, bushings, and
grommets.
Lift motor from plate.
See paragraphs 6.29 and 6.30 for motor repair.
Do not hammer fan on or off motor shaft;
motor bearings would be damaged.
Dress out roughness with a fine file,
stone, or abrasive cloth. Apply a coating
of light machine oil to ease assembly.
Slide collar or adapter onto motor shaft.
Tighten setscrew in collar or adapter.
NOTE
It maybe necessary to trial fit motor
mount bushings so fan will be cen-
tered in fan inlet.
Remarks
6-84
|