TM 9-4120-389-14
a.
Inspection
(1)
Check frame, cover and mounting plate for dents, cracks or punctures. Replace if damage
creates a hazard or interferes with operation.
(2)
Check that grommets are in place and not damaged. Replace as needed.
(3)
Check that information plate is readable.
(4)
Check information plate for dents, cracks or punctures. Replace as needed.
(5)
Check four posts for straightness and thread damage. Replace any defective post.
b.
Repair.
Repairs are limited to replacement of damaged or missing parts.
Follow-on procedures:
1.
Install temperature selector switch (See para. 4-43).
2.
Install connector (P2) with leads (See para. 4-42).
3.
Install mode selector switch (See para. 4-41).
4.
Install compressor circuit breaker (See para. 4-39).
5.
Install control circuit breaker (See para. 4-40).
6.
Install control module (See para. 4-38).
4-140
|