TM 9-4120-389-14
b. Removal
(1) Using wrench and screwdriver, remove eight locknuts and screws that secure connector J1 to
junction box.
(2) Cut ties as needed.
(3) Tag and disconnect all wire leads.
c. Test
(1) See wiring diagram (FO-1) and continuity test individual wires.
(2) Repair or replace wires with no continuity.
d. Repair
(1) See para. 4-36 for general wire repair instructions.
(2) See table 4-3 (wire list) for length and terminal connector information.
e. Installation
(1) Align eight holes in connector J1 to mounting hole in junction box.
(2) Secure connector J1 to junction box with eight screws and locknuts.
(3) See tags and wiring diagram (FO-1) and connect all wire leads. Remove
tags.
(4) Install ties as needed.
Follow-on procedures: Install junction box (See para. 4-46).
4-159
|