![]() TM9 4120-423-14&P
1
To remove the P4 to J15 wiring harness, disconnect the two quick-disconnect terminals to the air
temperature sensing probe. Disconnect plug P4 from the J4 connector on the electrical module.
2
To remove the P8 to P9 wiring harness, disconnect the plug P9 from the J9 through-bulkhead
connector.
3
To remove the J9 through-bulkhead connector, disconnect the P9A plug from inside the access
box. Using a screwdriver, socket, and ratchet, remove the four screws and locknuts. Carefully
remove the through-bulkhead connector and gasket.
4
To remove the J2 through-bulkhead connector, disconnect the P2 and P2A plugs from the top
and bottom of the connector. Using a screwdriver, socket, and ratchet, remove the four screws
and lock nuts. Carefully remove the through bulkhead connector and gasket.
5
Using a screwdriver, socket and ratchet, remove the four screws and locknuts from the remote
control harness connector (J7).
6
Remove the connector (J7) harness and connector gasket from the backside of the front
evaporator cover. Take care that the connector gasket is not lost.
7
Slide the radio frequency filter out and disconnect the P8 plug and harness from the backside of
the filter.
REPAIR OR REPLACEMENT
1
2
See wire list for wire lengths and terminal information when individual wires are replaced.
TEST AND INSPECTION
1
Check connectors for general condition, loose, broken, or missing contacts. Replace connectors
if damaged.
2
Check individual wires for loose solder connections, cut or frayed insulation, and cut or broken
wires.
3
See wiring diagram and continuity test individual wires. Repair or replace wires with no
4
Check that gaskets are in good condition. Replace them if they are torn, missing or otherwise
damaged.
0029 00-3
|