TM9 4120-423-14&P
6
To replace information plate, use a drill bit slightly smaller than the diameter of the rivet being
removed.
7
Drill the rivets out and remove the old plate.
8
Align holes in replacement plate and cover and install new rivets.
9
Minor dents and bent edges can be straightened using common sheet metal repair procedures.
Panels that are badly dented, bent, or punctured should be replaced.
10
Should touch up or refinishing be necessary, see WP0016.
11
Use only approved replacement material as specified in Chapter 8.
12
EMI gasket material specified for this unit is supplied with adhesive backing.
13
Cut gasket to size. Be sure that EMI gasket corners are mitered so that good continuous edge
contact is made.
14
Be sure that surface to which gasket is to be applied is clean and free of paint and old adhesive
material
15
Remove backing material from adhesive side and immediately press gasket in place. Be sure
that good edge-to-edge contact is made on the EMI gaskets.
16
Minor rips, cuts, tears, or punctures in fabric cover may be repaired by applying a patch to the
inside surface.
17
Metallic grommets and snap fasteners may be replaced if surrounding material is not damaged.
18
For damage of greater extent or if cover material is damaged so that metallic grommets and snap
fasteners cannot be replaced, replace the entire fabric cover.
INSTALLATION
1
Line up screw holes in fabric cover and the air conditioner housing.
2
Using screwdriver, install cover with three screws.
3
Roll cover up and tie both ties if unit is to be operational.
4
If unit is to be placed in storage, leave cover rolled down and snap in place.
5
Line up screw holes in top condenser cover and air conditioner housing.
6
Using screwdriver, install cover with fifteen screws.
0044 00-5
|