TM9 4120-423-14&P
TUBING AND FITTINGS (EVAPORATOR ASSEMBLY)
THIS WORK PACKAGE COVERS:
Repair or Replacement
Tools and Special Tools
Brazing Torch
Materials/Parts
Dehydrator MS35845-1
Personnel Required
Direct Support Technician
Equipment Conditions
Air conditioner removed from shelter (See
Evaporator coil and piping removed (See
REPAIR OR REPLACEMENT
1
The evaporator assembly contains a number of pieces of copper tubing in a variety of material
grades, sizes, lengths, and shapes and a number of elbows, tees, and adapters. Observe the
following when replacing any piece of tubing in the system.
WARNING
Be sure the refrigeration system is fully discharged and purged, and that dry nitrogen is
flowing through the system at a rate of less than 1-2 cfm (0.028 - 0.057 cubic
meters/minute) before all brazing or debrazing operations.
2
Replace tubing and fittings only with equal material, grade, size, length, and shape as the item
removed.