TM9 4120-423-14&P
3
Using screwdriver, install service valve with two screws.
4
Using wrench connect and tighten flare nut to back of valve.
5
Replace the dehydrator. (See WP0080).
6
Leak test the newly connected joints and all connections in those areas. (See WP0073).
7
8
Screw cap(s) in place on service valve(s).
9
Using hammer and punch, secure both chains to air conditioner housing with drive screw.
10
Install right end condenser cover. (See WP0045).
11
Install condenser section electrical module assembly. (See WP0051).
12
Connect power.
END OF TASK