TM 9-4120-425-14&P
ACCUMULATOR DIRECT SUPPORT MAINTENANCE REPLACEMENT - Continued
0071-00
WARNING
Ensure power source is disconnected. Ensure refrigerant system is discharged.
REMOVAL
1.
Remove insulation and adjacent wrapping sufficient to debraze tube connections.
2.
Debraze tubes connected to accumulator (3) (See WP 0051-00).
3.
Remove nut (1), flat washer (2), accumulator (1) from bracket (5).
4.
Bracket (5) can remain in place unless damaged.
NOTE
Observe direction of flow indicated on accumulator and install it to match flow
direction.
INSTALLATION
1.
Place accumulator (3) on bracket (5).
2.
Install nut (1) and flat washer (2) onto stud of accumulator (3).
3.
Braze the tube connections (See WP 0051-00).
4.
Replace the filter-drier (See WP 0066-00).
5.
Install insulation on accumulator (3) and tubing.
6.
Install condenser fan scroll (See WP 0062-00).
7.
Install condenser fan motor (See WP 0031-00).
8.
Install top rear panel (See WP 0019-00).
9.
Service the refrigeration system (See WP 0049 thru WP 0055-00).
0071-00-2
|