TM 9-4120-428-14
0035 00
TESTING
See the wiring diagram (WP 0028 00). Test continuity between individual wires and corresponding pin connectors.
Replace or repair wires with no continuity.
REPAIR
1. See WP 0028 00 for general wire repair instructions.
2. See WP 0028 00, Wire List for wire lengths and terminal information when individual wires are replaced.
REPLACEMENT
Replace the harness assembly if the connector receptacle (13) is damaged.
INSTALLATION
19. Fit the connector receptacle (13) into the back mounting plate (7) and secure it with seven machine screws (8), nuts (9),
and flat washers (10).
20. Install electrical post (12) and loop clamp (11). Secure with machine screw (8), flat washer (10), and self-locking nut (9)
21. See the tags and wiring diagram (WP 0028 00) and connect the wire leads. Remove tags.
22. Ensure that the grommets (14) are in place in the shaft holes.
23. Slip the back mounting plate (7) in place and align the holes in the back plate (7) with three spacer posts (6). Ensure the
grommets (14) are in place in the shaft holes. Secure with three self-locking screws (5).
24. Install the knob (4) and tighten the setscrew (3).
25. Slip the control cover (2) in place and secure with four machine screws (1).
NOTE
FOLLOW-ON MAINTENANCE:
Install control module (WP 0029 00)
0035 00-2
|