TM 9-4120-428-14
DIRECT SUPPORT MAINTENANCE
AIR CONDITIONER, HORIZONTAL, COMPACT
SERVICE (CHARGING) VALVES REPLACEMENT
INITIAL SETUP:
Equipment Condition
Tools
Remove top panels (WP 0061 00)
Refrigeration Unit Service Tool Kit, WP 0000 00, Item
Remove dehydrator (WP 0075 00)
1
Materials/Parts
Service Charging Valve
Lock Washer
REPLACEMENT
1. Remove screw (Figure 5 -26, Item 1), lock washer (2), flat washer (3), cap and chain (4), and loop clamp (5) from
the valve (6) to be replaced.
2. Disconnect the flare nut (7) and remove the valve (6).
3. Slip the valve (6) into place and tighten the flare nut (7).
4. Secure the valve (6) and cap and chain (4) with the loop clamp (5), screw (1), lock washer (2), and flat washer (3).
1
1
2
2
3
3
4
4
5
5
6
6
7
7
0085 00-1