TM 9-4120-430-14
0035 00
REASSEMBLY
1. Assemble motor (8) to motor mounting bracket (7) by inserting four screws (21) with flat washers (22) through
mounting holes. Secure motor (8) by installing flat washer (20) and locking nuts (19) onto screws (21).
2. Carefully insert impeller (6) into blower housing (13).
3. Attach inlet rings (18) to each end of blower housing with four lockwashers (17) and screws (16).
4. Attach evaporator blower rails (14) and (15) to blower housing with four lockwashers (12) and screws (11).
5. Position motor mounting bracket (7) with motor (8) between evaporator blower rails (14) and (15), sliding impeller
(6) onto motor shaft.
6. Secure motor mounting bracket (7) to evaporator blower rails (14) and (15) with lockwashers (10) and screw (9).
7. Tighten only the one setscrew (5) that is over the flat surface of the shaft to secure impeller (6) onto motor shaft.
8. Check position of impeller (6) to spin free and clear of housing. Readjust position as necessary.
INSTALLATION
1. Positions evaporator fan and housing assembly into unit housing and secure with four screws (1, Figure 1).
2. Install close off angle (3, Figure 2) onto firewall bracket (4) of the inner housing bulkhead and secure with two
lockwashers (2), and screws (1).
3. Place the temperature selector switch sensing bulb in clamp and tighten screw. Refer to figure 1, front view
illustration.
4. Install condensate drain tubing. See WP 0024 00.
5. Reconnect motor connections. Refer to wire list and schematic diagram (WP 0038 00).
6. Install the evaporator inlet louver. See WP 0020 00.
0035 00-3
|