MWO 55-8115-202-40-1
10a. Installation of Slide Kit, Exhaust Kit, and Supplemental Kit.
(1) Remove existing 10 kW MEP generator and fuel tank from framed end of container.
Reference TM 55-8115-202-14, Change 4 or lower, Paragraph 4-68, Figure 4-15 and TM 55-
8115-202-24P, Change 4 or lower, Figure 12. Some containers may have bolts anchoring the
generator to the frame in rear.
Paragraph 4-68 from TM 55-8115-202-14.
1. DISCONNECT CABLE CONNECTORS AND STOW 30-FT. CABLE INSIDE REFRIGERATION UNIT.
2. DISCONNECT FUEL LINE BETWEEN AUXILIARY TANK AND ENGINE FUEL LINE
CONNECTIONS, AND STOW FUEL LINE IN STORAGE BOX.
4. REMOVE CAPSCREWS AND WASHERS, 1,2 & 3 IN FIGURE 12.
5. REMOVE GENERATOR SET USING FORKLIFT TRUCK ENGAGED IN FORK LIFT POCKETS IN
SKID BASE.
6. DISCONNECT 5-FT. CABLE FROM GENERATOR SET AND STOW CABLE ON STORAGE
BRACKET.
Refer to TM 5-
6115-585-12/34
For Generator Set
Parts Breakdown
Figure 12 from TM 55-8115-202-14
(2) Cut, torch or grind off generator stop, front lip piece, from end of bottom horizontal frame
member (Figure 1A and 1B). If you choose to use the torch, you must adhere to local Standard
8
|