DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER MOTOR ASSEMBLY REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Tags, Identification (Item 9, Appendix E)
Field Level Maintenance
Tape, Insulation, Electrical (Item 10, Appendix E)
Equipment Condition
Personnel Required
Batteries disconnected (TM 9-2320-279-20).
MOS 52C, Utilities equipment repairer
AC upper plenums removed (WP 0045).
References
Tools and Special Tools
TM 9-2320-279-20
Tool Kit, General Mechanic's (Item 7, Appendix F)
REMOVAL
HEMAC073
1. Remove four screws (1), lockwashers (2), washers (3), and cover (4) from heater/evaporator (5).
|