DRAFT
TB 9-2320-279-13-1
AC LOWER PLENUM AND DAMPER REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Adhesive, 3M #1300 (Item 1, Appendix E)
Field Level Maintenance
Ties, Cable (Item 12, Appendix E)
Equipment Condition
Personnel Required
AC heater/evaporator removed (WP 0038).
MOS 52C, Utilities equipment repairer
Tools and Special Tools
References
Tool Kit, General Mechanic's (Item 7, Appendix F)
None
REMOVAL
HEMAC060
NOTE
Note position of damper prior to removal to ensure proper installation.
1. Remove damper (1) from lower plenum (2).
2. Remove four cable ties (3) and lower plenum (2) from four defrost tubes (4).
|