DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR REPLACEMENT
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
THIS WORK PACKAGE (WP) COVERS:
Removal
Installation
Follow-On Maintenance
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Materials/Parts
Maintenance Level
Solution, Soap (Item 7, Appendix E)
Field Level Maintenance
Tags, Identification (Item 9, Appendix E)
Equipment Condition
Ties, Cable (Item 13, Appendix E)
Batteries disconnected (TM 9-2320-279-20).
Personnel Required
Cooling system drained (TM 9-2320-279-20).
MOS 52C, Utilities equipment repairer (2)
Refrigerant recovered (WP 0050).
Skid plate grille removed (TM 9-2320-279-20).
References
AC upper plenums removed (WP 0045).
TM 9-2320-279-10
Tools and Special Tools
TM 9-2320-279-20
Set, Cap and Plug (Item 3, Appendix F)
Shop Equipment, Common No. 1 (Item 4,
Shop Equipment, Common No. 2 (Item 5,
Tool Kit, General Mechanic's (Item 7, Appendix F)
REMOVAL
HEMAC027
1. Loosen screw (1) and remove heater cable (2) from retainer (3).
2. Remove heater cable (2) from heater control valve (4).
|