TM 10-4110-262-13&P
UNIT MAINTENANCE
ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
IC POWER ENTRY CONNECTOR
REPAIR AND REPLACE
INITIAL SETUP
Personnel Required
Tools and special tools
Electrical Technician MOS 51 (AFSC 3E)
Tool Kit, Organizational Maintenance
References
Multimeter (WP 0051 00, Table 2, Item 2)
Materials and Parts
Equipment Conditions
IC Power Entry Connector
ADR-300 set up and connected to a power
(WP 0056 00, Item 4)
source (See WP 0005 00 for set-up
Sealant (WP 0068 00, Item 21)
procedures).
Putty Knife (WP 0068 00 Item 14)
GENERAL
This work package outlines steps for testing, repairing and replacing the power entry connector on the
rear of the IC exterior. Before beginning this procedure, complete the IC electrical system test outlined in
Work Package 0018 00. The power entry connector should only be replaced by an identical assembly or
an approved substitute.
REPAIR
1. Confirm that power is disconnected from the IC power entry connector.
2. Remove the four screws that retain the cover plate for the input connector.