TM 10-4110-262-13&P
DIRECT SUPPORT MAINTENANCE
ADVANCED DESIGN REFRIGERATOR, 300 CUBIC FOOT (ADR-300)
UNIT CONTROLLER
REMOVE/INSTALL
INITIAL SETUP
References
Tools and special tools
PMCS Instruction (WP 0010 00)
Tool Kit, Organizational Maintenance
Equipment Conditions
ADR-300 disconnected from all sources of
Materials and Parts
power.
Controller M13 (WP 0060 00, Item 9)
Personnel Required
HVAC Technician (MOS 52C, AFSC 3E1x1) (1)
REMOVE
1. Open the controller enclosure by turning the handle -turn.
2. Loosen one set screw on each side of the controller.
3. Gently remove the controller from the enclosure to the extent of the connected wires.
4. Slide the terminal cover plate off the controller by pinching the grip points.
5. Remove two terminal plug connectors from the back of the controller.
6. Remove the controller.
INSTALL
CAUTION
Be careful not to pinch the wires. Failure to comply may result in
damage to equipment.
CAUTION
Ensure terminal leads are firmly seated in the terminal connector. Leads
can pop out of the connector and continuity will be lost. Failure to
comply may result in damage to equipment.
1. Install the two terminal plug connectors in the back of the controller.
0036 00-1
|