Figure 1. Hot Gas Valve Coil Replacement.
MAINTAINER MAINTENANCE EVAPORATOR SENSORS INSPECT, REPLACE

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  427    428    429    430    431  432  433    434    435    436    437  
img
. .
TM 10-8145-222-23
0048
REPLACE CONTINUED
8. Reconnect electrical connector (Figure 1, Item 4) to hot gas valve coil (Figure 1, Item 5) as tagged during
disconnection.
9. Install liquid line solenoid coil (WP 0047, Replace).
10. Remove wire tags from wire leads (Figure 1, Item 4).
11. Close evaporator cover panel (Figure 1, Item 1) and secure using two bolts (Figure 1, Item 2) and two washers
(Figure 1, Item 3).
12. Reconnect battery (WP 0053, Reconnect).
13. Start refrigeration unit and verify proper operation (TM 10-8415-222-10, Operating Procedures).
14. Place MTRCS back into desired mode of operation (TM 10-8415-222-10, Operating Procedures).
END OF TASK
END OF WORK PACKAGE