Reconnect Battery and Voltage Check
Figure 2. Voltage Check of Battery.

TECHNICAL MANUAL FOR MULTI-TEMPERATURE REFRIGERATED CONTAINER SYSTEM
Page Navigation
  481    482    483    484    485  486  487    488    489    490    491  
img
TM 10-8145-222-23
0053
SERVICE CONTINUED
5. Turn multimeter to volts DC scale.
6. Connect positive (+) lead of multimeter to positive (+) battery terminal (Figure 2, Item 4).
7. Connect negative (-) lead of multimeter to negative (-) battery terminal (Figure 2, Item 5).
8. Verify battery (Figure 2, Item 1) voltage is between 11.0 and 13.4 volts DC. If voltage is not within 11.0 and 13.4
volts DC, replace battery in accordance with Remove and Install in this WP.
9. Remove multimeter leads from positive (+) battery terminal (Figure 2, Item 4), and negative (-) battery terminal
(Figure 2, Item 5).
10. Install battery box cover (Figure 2, Item 6).
11. Install battery box clamp (Figure 2, Item 10) over battery box cover (Figure 2, Item 6).
12. Install two L-bolts (Figure 2, Item 9) through lip on battery pan (Figure 2, Item 3) and through battery box clamp
(Figure 2, Item 10).
13. Secure two L-bolts (Figure 2, Item 9) to battery box clamp (Figure 2, Item 10) using two lock nuts (Figure 2,
Item 7) and flat washers (Figure 2, Item 8).
14. Tighten lock nuts (Figure 2, Item 7).
15. Place MTRCS back into desired mode of operation.
0053-4