TM 5-4110-217-14
(5) If the ambient temperature is other than
75F, see table 3-4 for correct voltage output.
(6) If voltage is not within limits specified,
replace regulator and repeat test.
(7) Increase load with carbon pile until
minimum rated current output is reached. Voltage at
output terminal should be at least 13 volts but should not
exceed maximum limits in table 3-4.
b. Removal.
(1) Disconnect cable from alternator at
connector.
(2) Remove
three
screws
(3)
and
lockwashers (2) securing voltage regulator (1) to
alternator.
c. Cleaning and Inspection.
(1) Clean voltage regulator with a clean lint-
free cloth.
(2) Inspect voltage regulator for cracks, chips,
dents and other damage. Replace if defective.
d. Installation.
1.
Nut, hex
4. Battery
7. Screw
(1) Align holes in voltage regulator (1) with
2. Bracket
5. Cable, battery, negative 8. Washer
holes in alternator as in original configuration and attach
3. Stud
6. Cable, battery, positive 9. Nut
with three screws (3) and lockwashers (2).
(2) Connect cable from alternator.
Figure 3-20. Battery (Model RMP-J1I-10G)
3-48.
Battery.
b.
a.
Charging.
(1) Remove two wing nuts (1) and
(1) Use any commercial type battery charger
studs (3) securing battery bracket (2) and battery (4).
for charging the battery. Refer to charger manufacturer's
(2) Remove battery cables (5 and 6) from
instructions for proper use of charger.
battery terminals.
(3) Lift battery (4) from battery well. (1)
NOTE
c. Cleaning and Inspection.
As a precautionary measure, disconnect
(1) Clean battery with an approved cleaning
positive battery terminal when charging
solvent and dry thoroughly.
battery in unit. Connecting charger in
(2) Inspect battery for cracks, chips, and
reverse will destroy the rectifier diodes in
other damage. Replace if defective.
alternator. Possible damage to regulator
d. Installation.
may occur if the battery is charged
without disconnecting the positive
CAUTION
battery terminal.
Most commercial
Observe proper polarity when installing
charges contain a high AC ripple voltage
battery, negative battery terminal must
which can be 4 or 5 volts in excess of
be grounded.
Reverse polarity will
the DC voltage indicated on charger
destroy the rectifier diodes in alternator.
This voltage may exceed the maximum
rating of rectifier diodes and regulator.
(1) Place battery (4) in battery well and
secure with two studs (3), brackets (2) and nuts (1).
(2) Connect battery cables (5 and 6) to proper
battery terminals.
Table 3-4. Maximum and Minimum Voltage Limits
Temperature
in degrees (F)
0
40
80
100
120
140
160
20
60
Minimum output terminal voltage
14.60
14.45
14.26
14 13
13.95
13 80
13.65
13.60
13.30
(10 amp load)
Maximum output terminal voltage 15 40
15.25
15.08
14 92
14 75
14.60
14.45
14.28
14 13
(12 amp load)
3-28
|