(e) R o l l u p t h e r m o s t a t s e n s i n g b u l b a n d
and connect the other end to the control panel
t u b e and secure to the rear of control panel utilizing
receptacle. The power cable may also be relocated
the retaining clamp. Connect the electrical con-
on the bulkhead or blockoff panel.
n e c t o r ( d i s c o n n e c t e d (b) above) to connector in
(f) T h e c o n n e c t i n g c a b l e m a y b e f a b r i c a t e d
bulkhead or blockoff. Install blockoff plate with
from an MS3106R-28-17S and MS3106R-28-17P
s c r e w s that mounted control panel. Connect a cable
straight plug electrical connector and the required
t o the receptacle in the bulkhead or blockoff plate
i n t e r c o n n e c t i n g length of Number 16 A WG wires.
a n d run it to the new location of the control panel
(g) R e i n s t a l l f r o n t a c c e s s p a n e l .
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |