![]() TM 5-4120-356-14
WARNING
Disconnect the air conditioner from the
e l e c t r i c a l power source before attempt-
ing to replace the heater elements or
electrical wiring.
(a) Replace electrical wiring or any heater element which shows
e v i d e n c e of damage which would impair serviceability or which fails during testing.
(b) If any heater element fails to function properly during test,
a n d wiring continuity checks OK, refer to step (3) and replace defective heater ele-
m e n t or elements.
(3) Remove and Install.
( a ) Turn selector switch to the "OFF" position and disconnect t h e
air conditioner from the electrical power source.
( b ) I f heater element or elements a r e t o b e r e p l a c e d , r e f e r t o f i g -
ure 3-27 for removal and installation.
(c)
R e i n s t a l l t o p p a n e l a s s e m b l y a n d fabric cover in accordance
w i t h paragraph 3-9.
H e a t e r Thermostatic Switch.
b.
WARNING
Disconnect the air conditioner from the
e l e c t r i c a l power source before attempt-
i n g to test or replace the heater ther-
mostatic switch.
(1)
Test.
( a ) T u r n s e l e c t o r s w i t c h to the "OFF" position and disconnect the
a i r c o n d i t i o n e r f r o m t h e e l e c t r i c a l p o w e r source.
( b ) R e m o v e f a b r i c c o v e r and top panel to gain access to the thermo-
s t a t i c switch in accordance with paragraph 3-9.
(c) Refer to figure 3-27 and remove the thermostatic switch.
(d) Refer to figure 3-29 and test the thermostatic switch.
( 2 ) R e p l a c e . R e p l a c e the thermostatic switch if any failure occurs
during testing in accordance with the procedures shown if figure 3-27.
( 3 ) I n s t a l l a t i o n . I n s t a l l the thermostatic switch in accordance with
t h e procedures shown in figure 3-27. R e i n s t a l l t o p p a n e l a n d f a b r i c c o v e r .
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |