TM 5-4120-356-14
TEST OF HEATER THERMOSTATIC SWITCH S4
NOTE
OPERATING TEMPERATURES
FOR HEATER THERMOSTATIC
SWITCH ARE AS FOLLOWS:
OPEN :
194F 5F
(90C 5C)
CLOSE :
110F 5F
(61C 5C)
PERFORM TEST AT AMBIENT
TEMPERATURE UNDER 194F
(90C).
1.
CHECK FOR CONTINUITY BETWEEN WIRE NUMBER 1 AND WIRE NUMBER 2.
2. CHECK FOR CONTINUITY BETWEEN WIRE NUMBER 1 AND WIRE NUMBER 3.
3. CHECK FOR CONTINUITY BETWEEN WIRE NUMBER, 2 AND WIRE NUMBER 3.
4. OPEN CIRCUIT BETWEEN ANY OF THE ABOVE POINTS CONSTITUTES FAIL-
URE OF THIS TEST.
TS54120356-14/329
Figure 3-29. Test of heater thermostatic switch S4
|