TM5-4120-376-14
5-18. CONDENSER LOUVER ACTUATOR AND CONTROL ASSY/Service, Adjust, Replace
(Cont)
LOCATION/ITEM
LOUVER CONTROL CABLES
Installation:
NOTE
The longer control cable assembly should be installed on the right side.
1. Align cable housings (12) with control cable housing mounting bracket (21) and secure with
four speed nuts (20).
2. Install two speed nuts (20) around control cable housing (12).
3. Align control cable housings (12) with condenser fan housings (22) and secure with two
speed nuts (20).
4. Align cable housing (12) with condenser fan housings and secure with two clamps (18) two
screws (16) and two lock washers (17).
5-30
|