TM5-4120-376-14
5-19. REFRIGERANT VALVES AND RELATED TUBING/Test, Repair, Replace (Cont)
LOCATION/ITEM
Removal:
NOTE
Always perform inspections, adjustments and test before removing refrigerant
components. The thermal expansion valve is hermetically sealed and cannot be
repaired.
11. Discharge the system in accordance with paragraph 5-8, page 5-10.
12. Remove one screw (10) one clamp (11) and one spacer post (12) securing quench valve (13)
to bulkhead.
13. Remove thermal mastic (Table D-1, Item 20) from bulb well (14).
14. Remove sensor bulb (15) from bulb well.
15
Debraze quench valve in accordance with paragraph 5-9 Page 5-11.
5-35
|